Journal of Biomechanics
Volume 35, Issue 1 , Pages 27-34 , January 2002

Flat medial–lateral conformity in total knee replacements does not minimize contact stresses

  • Jeremy J. Rawlinson

      Affiliations

    • Corresponding Author InformationCorresponding author. Mechanical and Aerospace Engineering, Cornell University, Upson Hall, Ithaca, NY 14853, USA. Tel.: +1-607-255-0994; fax: +1-607-255-1222
  • ,
  • Donald L. Bartel

,Accepted 8 August 2001.

References 

  1. Baldini, T., Wright, T., Bartel, D., Estupinan, J., 1999. Wear damage is affected by conformity in knee joint geometries. Transactions of the Society of Biomaterials, 25.
  2. Bartel D, Bicknell V, Wright T. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. Journal of Bone and Joint Surgery. 1986;68-A(7):1041–1051
  3. Bartel, D., Li, S., 1995. Use of polyethylene for total joint replacements. In: Advances in Operative Orthopaedics. Mosby—Year Book, Inc. St. Louis, MO.
  4. Bartel D, Rawlinson J, Burstein A, Ranawat C, Flynn W. Stresses in polyethylene components of contemporary total knee replacements. Clinical Orthopaedics. 1995;317:76–82
  5. Burstein, A., 1984. Biomechanics of the knee. In: Insall, J.N. (Ed.), Surgery of the Knee. Churchill-Livingstone, New York.
  6. Collier J, Mayor M, McNamara J, Surprenant V, Jensen R. Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clinical Orthopaedics. 1991;273:232–242
  7. Dennis D, Komistek R, Colwell C, Ranawat C, Scott R, Thornhill T. In vivo determination of condylar lift-off (a multicenter study). Transactions of the Orthopaedics Research Society. 1999;45:970
  8. Estupinan J, Bartel D, Wright T. Simulation of surface crack propagation in UHMWPE. Transactions of the Orthopaedics Research Society. 1998;23:703
  9. Harman M, Banks S, Natarajan R, Andriacchi T, Hofmann A, Hodge W. Analysis of retrieved flat-on-flat polyethylene inserts (Wear patterns are not consistent with medial edge loading after TKA). Transactions of the Orthopaedics Research Society. 1999;45:835
  10. Jin, Z., Dowson, D., Fisher, J., 1995. Contact pressure distribution in total knee joint replacements, Part 1: general elasticity solution for elliptical layered contacts. Proceedings of the Institution of Mechanical Engineers, Part H, 209, 1–8.
  11. Johnson K. Contact Mechanics. Cambridge, UK: Cambridge University Press; 1985;
  12. Kennedy F, Currier J, Plumet S, Duda J, Gestwick D, Collier J, et al. Contact fatigue failure of ultra-high molecular weight polyethylene bearing components of knee prostheses. Journal of Tribology. 2000;122(1):332–339
  13. Muskhelishvilli, N., 1953. Some Basic Problems of the Mathematical Theory of Elasticity, 3rd Edition (Translated: JRM Radok). P. Noordhoff Ltd., Groningen, Holland.
  14. Nayak L, Johnson K. Pressure between elastic bodies having a slender area of contact and arbitrary profiles. International Journal of Mechanical Sciences. 1979;21:237–247
  15. Rawlinson J, Armitage B, Bartel D. The need for nonlinear material models of UHMWPE. Transactions of the Orthopaedics Research Society. 1999;45:959
  16. Sathasivam S, Walker P. Optimization of the bearing surface geometry of total knees. Journal of Biomechanics. 1994;27(3):255–264
  17. Wright T, Fukubayashi T, Burstein A. The effect of carbon fiber reinforcement on contact area, contact pressure, and time-dependent deformation in polyethylene tibial components. Journal of Biomedical Materials Research. 1981;15:719–730

PII: S0021-9290(01)00172-5

Journal of Biomechanics
Volume 35, Issue 1 , Pages 27-34 , January 2002