Journal of Biomechanics
Volume 35, Issue 1 , Pages 19-26, January 2002

Scaling of peak moment arms of elbow muscles with upper extremity bone dimensions

  • Wendy M. Murray

      Affiliations

    • Rehab Research & Development Center (153), VA Palo Alto Health Care System, 3801 Miranda Avenue, Palo Alto, CA 94304, USA
    • Corresponding Author InformationCorresponding author. Tel.: +1-650-493-5000; fax: +1-650-493-4919
  • ,
  • Thomas S. Buchanan

      Affiliations

    • Mechanical Engineering Department, University of Delaware, Newark, DE 19716, USA
  • ,
  • Scott L. Delp

      Affiliations

    • Biomechanical Engineering Division, Mechanical Engineering Department, Stanford University, Stanford, CA 04305, USA

Accepted 24 August 2001.

Abstract 

It is often assumed that moment arms scale with size and can be normalized by body segment lengths or limb circumferences. However, quantitative scaling relationships between moment arms and anthropometric dimensions are generally not available. We hypothesized that peak moment arms of the elbow flexor and extensor muscles scale with the shorter distance (Ds) between the elbow flexion axis and a muscle's origin and insertion. To test this hypothesis, we estimated moment arms of six muscles that cross the elbow, digitized muscle attachment sites and bone surface geometry, and estimated the location of the elbow flexion axis in 10 upper extremity cadaveric specimens which ranged in size from a 5′0″ female to a 6′4″ male. Ds accurately reflected the differences in peak moment arms across different muscles, explaining 93–99% of the variation in peaks between muscles in the same specimen. Ds also explained between 55% and 88% of the interspecimen variation in peak moment arms for brachioradialis, biceps, and ECRL. Triceps peak moment arm was significantly correlated to the anterior–posterior dimension of the ulna measured at the olecranon (r2=0.61, p=0.008). Radius length provides a good measure of the interspecimen variation in peaks for brachioradialis, biceps, and ECRL. However, bone lengths were not significantly correlated to triceps moment arm or anterior–posterior bone dimensions. This work advances our understanding of the variability and scaling dimensions for elbow muscle moment arms across subjects of different sizes.

Keywords:  Elbow, Muscle, Moment arms, Scaling

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(01)00173-7

Journal of Biomechanics
Volume 35, Issue 1 , Pages 19-26, January 2002