Journal of Biomechanics
Volume 38, Issue 5 , Pages 1185-1190 , May 2005

Performance of orientation sensors for use with a functional electrical stimulation mobility system

  • Scott Simcox

      Affiliations

    • Rehabilitation Research Centre, The University of Sydney, Australia
    • Corresponding Author InformationCorresponding author. University of Sydney, Faculty of Health Science, P.O. Box 170, Lidcombe, NSW 2141, Australia. Tel.: +61-2-9351-9650; fax: +61-2-9351-9977
  • ,
  • Simon Parker

      Affiliations

    • Neopraxis Pty. Ltd., Lane Cove, Australia
  • ,
  • Glen M Davis

      Affiliations

    • Rehabilitation Research Centre, The University of Sydney, Australia
  • ,
  • Richard W Smith

      Affiliations

    • School of Exercise and Sports Science, The University of Sydney, Australia
  • ,
  • James W Middleton

      Affiliations

    • Rehabilitation Studies Unit, Department of Medicine, The University of Sydney, Australia

,Accepted 25 May 2004.

References 

  1. Crago PE, Chizeck HJ, Neuman MR, Hambrecht FT. Sensors for use with functional neuromuscular stimulation. IEEE Transactions on Biomedical Engineering. 1986;33:256–268
  2. Davis R, Houdayer T, Andrews BBarriskill, A . Paraplegia (Prolonged standing using closed-loop functional electrical stimulation and andrews ankle-foot orthosis). Artificial Organs. 1999;23:418–420
  3. Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions (Application to the knee). Journal of Biomechnical Engineering. 1983;105:136–144
  4. Luinge HJ, Veltink PH, Baten CT. Estimating orientation with gyroscopes and accelerometers. Technology and Health Care. 1999;7:455–459
  5. Mayagoitia RE, Nene AV, Veltink PH. Accelerometer and rate gyroscope measurement of kinematics (An inexpensive alternative to optical motion analysis systems). Journal of Biomechnics. 2002;35:537–542
  6. Miyazaki S. Long-term unrestrained measurement of stride length and walking velocity utilizing a piezoelectric gyroscope. IEEE Transactions on Biomedical Engineering. 1997;44:753–759
  7. Pappas IP, Popovic MR, Keller T, Dietz V, Morari M. A reliable gait phase detection system. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 2001;9:113–125
  8. Petrofsky JS, Phillips CA. Closed-loop control of movement of skeletal muscle. Critical Review in Biomedical Engineering. 1985;13:35–96
  9. Popovic MR, Keller T, Pappas IP, Dietz V, Morari M. Surface-stimulation technology for grasping and walking neuroprosthesis. IEEE Engineering Medicine and Biology Magazine. 2001;20:82–93
  10. Skelly MM, Chizeck HJ. Real-time gait event detection for paraplegic FES walking. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 2001;9:59–68
  11. Tong KGranat, M.H . A practical gait analysis system using gyroscopes. Medical Engineering Physics. 1999;21:87–94
  12. Willemsen AT, Bloemhof F, Boom HB. Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation. IEEE Transactions Biomedical Engineering. 1990;37:1201–1208
  13. Williamson R, Andrews BJ. Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes. Medical and Biological Engineering and Computing. 2001;39:294–302
  14. Williamson R, Andrews BJ. Gait event detection for FES using accelerometers and supervised machine learning. IEEE Transactions on Rehabilitation Engineering. 2000;8:312–319
  15. Williamson R, Andrews BJ. Sensor systems for lower limb functional electrical stimulation (FES) control. Medical Engineering and Physics. 2000;22:313–325

PII: S0021-9290(04)00266-0

doi: 10.1016/j.jbiomech.2004.05.026

Journal of Biomechanics
Volume 38, Issue 5 , Pages 1185-1190 , May 2005