Journal of Biomechanics
Volume 38, Issue 5 , Pages 1075-1083, May 2005

Cruciate coupling and screw-home mechanism in passive knee joint during extension–flexion

Department of Mechanical Engineering, Division of Applied Mechanics, École Polytechnique, P.O. Box 6979, Station Centre-ccue, Montréal, Québec, Canada, H3C 3A7

Accepted 26 May 2004. published online 19 August 2004.

Abstract 

The screw-home mechanism and coupling between forces in cruciate ligaments during passive knee joint flexion were investigated for various boundary conditions, flexion axis alignments and posterior cruciate ligaments (PCL)/anterior cruciate ligament (ACL) conditions. A developed non-linear 3D finite element model was used to perform detailed elasto-static response analyses of the human tibiofemoral joint as a function of flexion angle varying from 10° hyper-extension to 90° flexion. The tibia rotated internally as the femur flexed and externally as the femur extended. The re-alignment of the flexion axis by ±5° rotation about the axial (distal-proximal) axis, transection of the ACL and changes in cruciate ligament initial strains substantially influenced the ‘screw-home’ motion. On the other hand, restraint on this coupled rotation diminished ACL forces in flexion. A remarkable coupling was predicted between ACL and PCL forces in flexion; forces in both cruciate ligaments increased as the initial strain or pretension in one of them increased whereas they both diminished as one of them was cut or became slack. This has important consequences in joint functional biomechanics following a ligament injury or replacement surgery and, hence, in the proper management of joint disorders.

Keywords:  Tibiofemoral joint, Flexion, Finite element method, Coupling, Screw-home motion

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(04)00280-5

doi:10.1016/j.jbiomech.2004.05.033

Journal of Biomechanics
Volume 38, Issue 5 , Pages 1075-1083, May 2005