Journal of Biomechanics
Volume 38, Issue 9 , Pages 1798-1806, September 2005

Local plantar pressure relief in therapeutic footwear: design guidelines from finite element models

  • Ahmet Erdemir

      Affiliations

    • Department of Biomedical Engineering/ND20, The Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA
  • ,
  • Jeffrey J. Saucerman

      Affiliations

    • Department of Bioengineering, University of California, San Diego, La Jolla, CA 92093-0412, USA
  • ,
  • David Lemmon

      Affiliations

    • The Methodology Center, The Pennsylvania State University, University Park, PA 16802, USA
  • ,
  • Bryan Loppnow

      Affiliations

    • Center for Locomotion Studies, The Pennsylvania State University, University Park, PA 16802, USA
  • ,
  • Brie Turso

      Affiliations

    • Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
  • ,
  • Jan S. Ulbrecht

      Affiliations

    • Departments of Biobehavioral Health and Medicine, The Pennsylvania State University, University Park, PA 16802, USA
  • ,
  • Peter Re Cavanagh

      Affiliations

    • Department of Biomedical Engineering/ND20, The Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA
    • Orthopaedic Research Center, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA
    • Corresponding Author InformationCorresponding author. Tel.: 2164456980; fax: 2164456083.

Accepted 2 September 2004. published online 23 November 2004.

Abstract 

A major goal of therapeutic footwear in patients with pain or those at risk for skin injury is to relieve focal loading under prominent metatarsal heads. One frequent approach is to place plugs of compliant material into the midsole of the shoe. This study investigated 36 plug designs, a combination of three materials, six geometries, and two placements using a two-dimensional (2D) finite element model. Realistic loading conditions were obtained from plantar pressures (PP) recorded during walking in five subjects who wore control midsoles manufactured using Microcell Puff. Measured peak pressures underneath the second metatarsal head were similar to the results of the control model. PP obtained from simulations with the plugs built into a firm midsole were compared to the simulation results of the control midsole. Large plugs (e.g. 40mm width), made out of Microcell Puff Lite or Plastazote Medium, placed at peak pressure sites, resulted in highest reductions in peak pressures (18–28%). Smaller plugs benefited from tapering when placed at high pressure areas. Case studies were completed on a healthy male subject and a diabetic female patient to address the efficacy of a plug design favored by our simulations (pressure based placement, 40×20mm, Plastazote Medium). Successful reductions of second metatarsal head pressures were observed with a mediolateral load redistribution that was not represented by our model. 2D computer simulations allowed systematic investigation of plug properties without the need for high volume experimentation on human subjects and established basic guidelines for plug selection. In particular, plugs that are placed based on plantar pressure measurements were proven to be more effective when compared to those positioned according to the projection of the bony landmark on the foot-shoe plantar contact area.

Keywords: Footwear, Insole, Midsole, Soft tissue, Plantar pressure, Finite element model

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(04)00436-1

doi:10.1016/j.jbiomech.2004.09.009

Journal of Biomechanics
Volume 38, Issue 9 , Pages 1798-1806, September 2005