Journal of Biomechanics
Volume 39, Issue 8 , Pages 1435-1443, 2006

Finite element analysis of a total ankle replacement during the stance phase of gait

  • B. Reggiani

      Affiliations

    • Bioengineering Science Research Group, School of Engineering Sciences, University of Southampton, Highfield, Southampton, SO17 1BJ, UK
    • DIEM – Dipartimento di Ingegneria delle Costruzioni Meccaniche, Nucleari, Aeronautiche e di Metallurgia, Università degli Studi di Bologna, Viale Risorgimento 2, 40136, Bologna, Italy
    • Corresponding Author InformationCorresponding author. DIEM – Dipartimento di Ingegneria delle Costruzioni Meccaniche, Nucleari, Aeronautiche e di Metallurgia, Università degli Studi di Bologna, Viale Risorgimento 2 40136, Bologna, Italy. Tel.: +390512093437; fax: +390512093412.
  • ,
  • A. Leardini

      Affiliations

    • Movement Analysis Laboratory, Istituti Ortopedici Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
  • ,
  • F. Corazza

      Affiliations

    • Movement Analysis Laboratory, Istituti Ortopedici Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
    • DIEM – Dipartimento di Ingegneria delle Costruzioni Meccaniche, Nucleari, Aeronautiche e di Metallurgia, Università degli Studi di Bologna, Viale Risorgimento 2, 40136, Bologna, Italy
  • ,
  • M. Taylor

      Affiliations

    • Bioengineering Science Research Group, School of Engineering Sciences, University of Southampton, Highfield, Southampton, SO17 1BJ, UK

Accepted 8 April 2005. published online 14 June 2005.

Abstract 

Total ankle replacement (TAR) designs have still several important issues to be addressed before the treatment becomes fully acceptable clinically. Very little is known about the performance, in terms of the contact pressures and kinematics of TAR when subjected to daily activities such as level gait. For this purpose, an explicit finite element model of a novel 3-component TAR was developed, which incorporated a previously validated mechanical model of the ankle ligament apparatus. The intermediate mobile polyethylene meniscal bearing was modelled as an elastic–plastic continuum while the articulating surfaces of the tibial and talar metal components as rigid bodies. Overall kinematics, contact pressures and ligament forces were analysed during passive, i.e. virtually unloaded, and active, i.e. stance phase of gait, conditions. Simulation of passive motion predicted similar kinematics as reported previously in an analytical four-bar linkage model. The meniscal bearing was observed to move 5.6mm posteriorly during the simulated stance and the corresponding antero-posterior displacement of the talar component was 8.3mm. The predicted pattern and the amount (10.6°) of internal–external rotation of the ankle complex were found to be in good agreement with corresponding in vivo measurements on normal ankles. A peak contact pressure of 16.8MPa was observed, with majority of contact pressures below 10MPa. For most ligaments, reaction forces remain within corresponding physiological ranges. A first realistic representation of the biomechanical behaviour of the human ankle when replaced by prosthetic joints is provided. The applied methodology can potentially be applied to other TAR designs.

Keywords: Total ankle replacement, Gait, Stance phase, Ligamentous apparatus, FE analysis, Full conformity, Kinematics analysis, Contact pressure

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(05)00178-8

doi:10.1016/j.jbiomech.2005.04.010

Journal of Biomechanics
Volume 39, Issue 8 , Pages 1435-1443, 2006