Journal of Biomechanics
Volume 40, Issue 12 , Pages 2636-2644, 2007

Learning to walk with a robotic ankle exoskeleton

  • Keith E. Gordon

      Affiliations

    • Division of Kinesiology, University of Michigan, 401 Washtenaw Avenue, Ann Arbor, MI 48109-2214, USA
    • Corresponding Author InformationCorresponding author. Rehabilitation Institute of Chicago, 345 E. superior St., Rm. 1406, Chicago, IL 60611, USA. Tel.: +13122382996; fax: +13122382208.
  • ,
  • Daniel P. Ferris

      Affiliations

    • Division of Kinesiology, University of Michigan, 401 Washtenaw Avenue, Ann Arbor, MI 48109-2214, USA
    • Department of Biomedical Engineering, University of Michigan, 401 Washtenaw Avenue, Ann Arbor, MI 48109-2214, USA
    • Department of Physical Medicine and Rehabilitation, University of Michigan, 401 Washtenaw Avenue, Ann Arbor, MI 48109-2214, USA

Accepted 5 December 2006. published online 05 February 2007.

Abstract 

We used a lower limb robotic exoskeleton controlled by the wearer's muscle activity to study human locomotor adaptation to disrupted muscular coordination. Ten healthy subjects walked while wearing a pneumatically powered ankle exoskeleton on one limb that effectively increased plantar flexor strength of the soleus muscle. Soleus electromyography amplitude controlled plantar flexion assistance from the exoskeleton in real time. We hypothesized that subjects’ gait kinematics would be initially distorted by the added exoskeleton power, but that subjects would reduce soleus muscle recruitment with practice to return to gait kinematics more similar to normal. We also examined the ability of subjects to recall their adapted motor pattern for exoskeleton walking by testing subjects on two separate sessions, 3 days apart. The mechanical power added by the exoskeleton greatly perturbed ankle joint movements at first, causing subjects to walk with significantly increased plantar flexion during stance. With practice, subjects reduced soleus recruitment by ∼35% and learned to use the exoskeleton to perform almost exclusively positive work about the ankle. Subjects demonstrated the ability to retain the adapted locomotor pattern between testing sessions as evidenced by similar muscle activity, kinematic and kinetic patterns between the end of the first test day and the beginning of the second. These results demonstrate that robotic exoskeletons controlled by muscle activity could be useful tools for testing neural mechanisms of human locomotor adaptation.

Keywords: Gait, Motor learning, Biomechanics, Powered orthosis, Locomotion, EMG

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(06)00486-6

doi:10.1016/j.jbiomech.2006.12.006

Journal of Biomechanics
Volume 40, Issue 12 , Pages 2636-2644, 2007