Journal of Biomechanics
Volume 40, Issue 16 , Pages 3598-3606, 2007

A numerical study of the flow-induced vibration characteristics of a voice-producing element for laryngectomized patients

  • S.L. Thomson

      Affiliations

    • Department of Mechanical Engineering, Brigham Young University, 435 CTB, Provo, UT, USA
    • Corresponding Author InformationCorresponding author. Tel.: +18014224980; fax: +18014220516.
  • ,
  • J.W. Tack

      Affiliations

    • Department of BioMedical Engineering, University Medical Center Groningen, University of Groningen, The Netherlands
  • ,
  • G.J. Verkerke

      Affiliations

    • Department of BioMedical Engineering, University Medical Center Groningen, University of Groningen, The Netherlands
    • Department of Biomechanical Engineering, University of Twente, The Netherlands

Accepted 6 June 2007. published online 28 July 2007.

Abstract 

A computational model for exploring the design of a voice-producing voice prosthesis, or voice-producing element (VPE), is presented. The VPE is intended for use by laryngectomized patients who cannot benefit from current speech rehabilitation techniques. Previous experiments have focused on the design of a double-membrane voice generator as a VPE. For optimization studies, a numerical model has been developed. The numerical model introduced incorporates the finite element (FE) method to solve for the flow-induced vibrations of the VPE system, including airflow coupled with a mass-loaded membrane. The FE model includes distinct but coupled fluid and solid domains. The flow solver is governed by the incompressible, laminar, unsteady Navier–Stokes equations. The solid solver allows for large deformation, large strain, and collision. It is first shown that the model satisfactorily represents previously published experimental results in terms of frequency and flow rate, enabling the model for use as a design tool. The model is then used to study the influence of geometric scaling, membrane thickness, membrane stiffness, and slightly convergent or divergent channel geometry on the model response. It is shown that physiological allowable changes in the latter three device parameters alone will not be sufficient to generate the desired reduction in fundamental frequency. However, their effects are quantified and it is shown that membrane stiffness and included angle should be considered in future designs.

Keywords: Voice-producing element, Voice prosthesis, Flow-induced vibrations, Finite element model, Total laryngectomy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(07)00266-7

doi:10.1016/j.jbiomech.2007.06.007

Journal of Biomechanics
Volume 40, Issue 16 , Pages 3598-3606, 2007