Journal of Biomechanics
Volume 40, Issue 16 , Pages 3615-3625, 2007

Long-term study of bone remodelling after femoral stem: A comparison between dexa and finite element simulation

  • Antonio Herrera

      Affiliations

    • Department of Surgery, University of Zaragoza, Spain
    • Department of Orthopaedic Surgery and Traumatology, Miguel Servet University Hospital, Zaragoza, Spain
    • Corresponding Author InformationCorresponding author. Department of Orthopaedic Surgery and Traumatology, Miguel Servet University Hospital, Paseo de Isabel la Católica, 1-3, 50009 Zaragoza, Spain. Tel.: +34976765664; fax: +34976765652.
  • ,
  • Juan J. Panisello

      Affiliations

    • Department of Surgery, University of Zaragoza, Spain
    • Department of Orthopaedic Surgery and Traumatology, Miguel Servet University Hospital, Zaragoza, Spain
  • ,
  • Elena Ibarz

      Affiliations

    • Department of Mechanical Engineering, University of Zaragoza, Spain
  • ,
  • Jose Cegoñino

      Affiliations

    • Department of Mechanical Engineering, University of Zaragoza, Spain
  • ,
  • Jósé A. Puértolas

      Affiliations

    • Department of Science and Technology of Materials, University of Zaragoza, Spain
  • ,
  • Luis Gracia

      Affiliations

    • Department of Mechanical Engineering, University of Zaragoza, Spain

Accepted 7 June 2007. published online 07 August 2007.

Abstract 

A hip replacement with a cemented or cementless femoral stem produces an effect on the bone called adaptive remodelling, attributable to mechanical and biological factors. The objective of all of cementless prostheses designs has been to achieve a perfect transfer of loads in order to avoid stress-shielding, which produces an osteopenia. In order to quantify this, the long term and mass-produced study with dual energy X-ray absorptiometry (DEXA) is necessary. Finite element (FE) simulation makes possible the explanation of the biomechanical changes which are produced in the femur after stem implantation. The good correlation obtained between the results of the FE simulation and the densitometric study allow, on one hand, to explain from the point of view of biomechanical performance the changes observed in bone density in the long-term, where it is clear that these are due to a different transfer of load in the implanted model compared to the healthy femur; on the other hand, it validates the simulation model, in a way that it can be used in different conditions and at different time periods, to carry out a sufficiently precise prediction of the evolution of the bone density from the biomechanical behaviour in the interaction between the prosthesis and femur.

Keywords: Bone remodelling, Finite element analysis, Hip replacement prosthesis

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(07)00268-0

doi:10.1016/j.jbiomech.2007.06.008

Journal of Biomechanics
Volume 40, Issue 16 , Pages 3615-3625, 2007