Abstract 

Endplate strength plays an important role in preventing vertebral failure of normal vertebrae and in cases where surgical intervention has replaced the disc with an implant or has altered the vertebral loading. We have developed a non-contact method based on the principles of image guided failure analysis, mechanical testing, and micro-computed tomography analysis, which allows for in vitro quantification of endplate deformation under axial load. The method allows for the implementation of a repeated measures experimental design, each specimen acting as its own control. Our methodology was validated using cadaveric functional spine units, loaded stepwise from 200N to a maximum of 2000N. The loading protocol was repeated over two days, allowing time for recovery of the disc mechanical properties. We found no meaningful difference in measured force, stiffness, and endplate deformation between day 1 and day 2. The mean fiducial registration error was less than 0.015mm for all three axes. Endplate deformation could be reproducibly estimated. The root mean squared error was 0.03mm, which is the effective precision of the method. Using this micro-CT based method, the effect of interbody implants, grafts, disc replacement strategies, and surgical procedures such as nucleotomy and vertebral cement augmentation on endplate mechanical behaviour can be ascertained.

Keywords: Micro-CT, Spine, Vertebra, Endplate, Deformation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(07)00332-6

doi:10.1016/j.jbiomech.2007.07.018

Journal of Biomechanics
Volume 41, Issue 1 , Pages 78-85, 2008