Journal of Biomechanics
Volume 42, Issue 3 , Pages 217-222, 9 February 2009

Measurement of body segment parameters using dual energy X-ray absorptiometry and three-dimensional geometry: An application in gait analysis

  • Mei Kay Lee

      Affiliations

    • School of Sports, Health and Leisure, Republic Polytechnic, 9 Woodlands Avenue 9, Singapore 738964, Singapore
    • Physical Education and Sports Science, National Institute of Education, 1 Nanyang Walk, Singapore 637616, Singapore
    • Corresponding Author InformationCorresponding author at: School of Sports, Health and Leisure, Republic Polytechnic, 9 Woodlands Avenue 9, Singapore 738964, Singapore. Tel.: +65631001207; fax: +6564151310.
  • ,
  • Ngoc Sang Le

      Affiliations

    • Department of Computer Science, National University of Singapore, 21 Lower Kent Ridge Road, Singapore 119077, Singapore
  • ,
  • Anthony C. Fang

      Affiliations

    • Department of Computer Science, National University of Singapore, 21 Lower Kent Ridge Road, Singapore 119077, Singapore
  • ,
  • Michael T.H. Koh

      Affiliations

    • School of Sports, Health and Leisure, Republic Polytechnic, 9 Woodlands Avenue 9, Singapore 738964, Singapore

Accepted 26 October 2008. published online 23 December 2008.

Abstract 

Body segment parameters (BSP) are essential input for the computations in kinetics of motion applied in the field of biomechanics. These data are usually obtained from population-specific predictive equations which present limitations in being representative of the population under study. More recently, medical imaging techniques have been adopted but are limited to two-dimensional (2-D) measurements or required extensive tomographic images for three-dimensional (3-D) reconstruction. We proposed an in vivo method to measure 3-D BSP using X-ray imaging and 3-D exterior geometry. Criterion values of the BSP were determined using magnetic resonance imaging (MRI) which has previously been validated. Errors for all BSP values were less than 2% when values derived from our method were compared to the criterion values. We found no significant difference between our method and four selected BSP models in both stance and swing phase. Significant phase effects were observed for our method and other BSP models between stance and swing phase. Significant differences (p<0.05) between root mean square error (RMSE) ranged from 0.0177 to 0.0234 and 0.0234 to 0.097Nmkg−1 for the knee and hip joints, respectively. However, these BSP variations brought about effects on moment output that were less than 0.09Nmkg−1. Our findings suggest joint kinetic computations during normal gait are relatively insensitive to BSP variations. However, the influence of BSP cannot be undermined in movements that generate higher acceleration at the limbs. Considering the accuracy of our method, it could be used as a novel in vivo method to obtain direct 3-D BSP measurements.

Keywords: Body segment parameters, Dual energy absorptiometry X-ray, 3-D geometry, Gait

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(08)00544-7

doi:10.1016/j.jbiomech.2008.10.036

Journal of Biomechanics
Volume 42, Issue 3 , Pages 217-222, 9 February 2009