In-vitro experimental assessment of a new robust algorithm for hip joint centre estimation

  • Elena De Momi

      Affiliations

    • NearLab, Dipartimento di Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
    • Corresponding Author InformationCorresponding author.
  • ,
  • Nicola Lopomo

      Affiliations

    • NearLab, Dipartimento di Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
    • Istituti Ortopedici Rizzoli, Bologna, Italy
  • ,
  • Pietro Cerveri

      Affiliations

    • NearLab, Dipartimento di Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
  • ,
  • Stefano Zaffagnini

      Affiliations

    • Istituti Ortopedici Rizzoli, Bologna, Italy
  • ,
  • Marc R. Safran

      Affiliations

    • University Medical Center, Stanford, CA, USA
  • ,
  • Giancarlo Ferrigno

      Affiliations

    • NearLab, Dipartimento di Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy

Accepted 26 February 2009. published online 27 April 2009.

Abstract 

Hip joint centre (HJC) localization is used in several biomedical applications, such as movement analysis and computer-assisted orthopaedic surgery.

The purpose of this study was to validate in vitro a new algorithm (MC-pivoting) for HJC computation and to compare its performances with the state-of-the-art (least square approach–LSA). The MC-pivoting algorithm iteratively searches for the 3D coordinates of the point belonging to the femoral bone that, during the circumduction of the femur around the hip joint (pivoting), runs the minimum length trajectory. The algorithm was initialized with a point distribution that can be considered close to a Monte Carlo simulation sampling all around the LSA estimate.

The performances of the MC-pivoting algorithm, compared with LSA, were evaluated with tests on cadavers. Dynamic reference frames were applied on both the femur and the pelvis and were tracked by an optical localizer.

Results proved the algorithm accuracy (1.7mm±1.6, 2.3—median value±quartiles), reliability (smaller upper quartiles of the errors distribution with respect to LSA) and robustness (reduction of the errors also in case of large pelvis displacements).

Keywords: Hip kinematics, Computer-assisted orthopaedic surgery, Functional hip joint centre, Motion analysis

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(09)00116-X

doi:10.1016/j.jbiomech.2009.02.031

Journal of Biomechanics
Volume 42, Issue 8 , Pages 989-995, 29 May 2009