Journal of Biomechanics
Volume 43, Issue 5 , Pages 879-886, 22 March 2010

Finite element analysis of barbed sutures in skin and tendon tissues

  • N.P. Ingle

      Affiliations

    • Department of Textile Engineering, Chemistry and Science, College of Textiles, 2401 Research Drive, North Carolina State University, Raleigh, NC 27695-8301, USA
    • Joint Department of Biomedical Engineering at North Carolina State University and University of North Carolina—Chapel Hill, Raleigh, NC 27695-7115, USA
  • ,
  • M.W. King

      Affiliations

    • Department of Textile Engineering, Chemistry and Science, College of Textiles, 2401 Research Drive, North Carolina State University, Raleigh, NC 27695-8301, USA
    • College of Textiles, Donghua University, Shanghai 201620, PR China
    • Corresponding Author InformationCorresponding author at: Department of Textile Engineering, Chemistry and Science, College of Textiles, 2401 Research Drive, North Carolina State University, Raleigh, NC 27695-8301, USA. Tel.: +19192912563; fax: +19195156532.
    web address
  • ,
  • M.A. Zikry

      Affiliations

    • Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695-7910, USA

Accepted 7 November 2009. published online 04 January 2010.

Abstract 

Barbed surgical sutures are a new type of knotless suture that are currently being used clinically in cosmetic and plastic surgery procedures for faster healing and better cosmesis. Clinical studies are also underway to evaluate their performance in other deep tissue applications. However, little is known about their intrinsic mechanical behavior and their interactions with surrounding tissues. The primary objective of the current study was to analyze the mechanical behavior of barbed sutures using a finite element analysis approach. First, the effect of applying a point-pressure load to the tip of the barb and measuring its effect on barb displacement was studied. Second, the effect of an applied displacement to a barb anchored either in skin or tendon material for both the suture and the surrounding tissue. The results indicate that the flexibility of the barb can be increased or decreased by changing the barb geometry. It was concluded that the barb geometry and design need to be modified for use with different types of tissue. For example, in order to achieve the best mechanical anchoring with skin tissue the barb should be more flexible compared to the one designed to work with tendon tissue. The uniqueness of this study is that it is the first to establish a virtual prototyping and designing method for barbed sutures. For example, a new and improved virtual design of barb geometry is proposed and validated. It also provides the first report on how to develop a virtual bench top suture/tissue pullout testing environment.

Keywords: Finite element analysis, Suture, Barbed, Tendon, Skin, Tissue

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(09)00648-4

doi:10.1016/j.jbiomech.2009.11.012

Journal of Biomechanics
Volume 43, Issue 5 , Pages 879-886, 22 March 2010