Journal of Biomechanics
Volume 43, Issue 5 , Pages 871-878, 22 March 2010

Assessment of amputee socket–stump–residual bone kinematics during strenuous activities using Dynamic Roentgen Stereogrammetric Analysis

MOVE Center, College of Engineering and Applied Science, Wisconsin Institute for Biomedical Health Technology, University of Wisconsin Milwaukee, Milwaukee, WI, USA

Accepted 7 November 2009. published online 04 January 2010.

Abstract 

The design, construction, and fitting of artificial limbs remain to this day an art, dependent on the accumulated expertise of the practitioner/prosthetist. Socket fitting is cost ineffective, time consuming, and a source of inconvenience for the amputee. Stump–skin slippage within the socket can cause discomfort, internal limb pain, and eventually skin ulcers as a result of excessive pressure and shear within the socket. This study presents a new method of assessment of three-dimensional (3D) socket–stump kinematics/slippage of strenuous activities using Biplane Dynamic Roentgen Stereogrammetric Analysis instrumentation. Ten below knee amputees participated in the study. A more holistic representation of the downward slippage trend of all proximal side skin markers with respect to the socket, and an even more characteristic and of higher magnitude downward-and anterioposterior slippage (maximum slippage: 151mm for the fast-stop task and 19mm for the step-down task) between the distal markers after impact, was possible for both tasks for all amputees. Displacement between skin-to-skin marker pairs reached maximum values of approximately 10mm for the step-down trials and up to 24mm for the fast stop trials. Maximum skin strain was dependent on the position of the skin markers. Distally positioned skin marker pairs demonstrated mainly anterioposterior displacement between each other (maximum relative strain: 13–14%). Maximum relative strain for the proximal markers was 8–10%. This highly accurate, in-vivo, patient-specific, unobtrusive dynamic information, presented using 3D visualization tools that were up to now unavailable to the clinician-prosthetist, can significantly impact the iterative cycle of socket fitting and evaluation.

Keywords: Amputee, Socket–stump kinematics, Dynamic radiography

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(09)00649-6

doi:10.1016/j.jbiomech.2009.11.013

Journal of Biomechanics
Volume 43, Issue 5 , Pages 871-878, 22 March 2010