Journal of Biomechanics
Volume 43, Issue 9 , Pages 1761-1770, 18 June 2010

Load transfer along the bone–dental implant interface

Northeastern University, Department of Mechanical Engineering, Boston, MA 02115, USA

Accepted 11 February 2010. published online 04 March 2010.

Abstract 

In this paper the variation of normal and shear stresses along a path defined on the bone–dental implant interface is investigated. In particular, the effects of implant diameter, collar length and slope, body length, and the effects of four different types of external threads on the interfacial stress distribution are studied. The geometry of the bone is digitized from a CT scan of a mandibular incisor and the surrounding bone. The bone and the implant are assumed to be perfectly bonded. The finite element method with 2D plane strain assumption is used to compute interfacial stresses. Highest continuous interfacial stresses are encountered in the region where the implant collar engages the cortical region, and near the apex of the implant in the subcortical region. Stress concentrations in the interfacial stresses occur near the geometric discontinuities on the implant contour, and jumps in stress values occur where the elastic modulus of the bone transitions between the cortical and trabecular bone values. Among the six contour parameters, the slope and the length of the implant collar, and the implant diameter influence the interfacial stress levels the most, and the effects of changing these parameters are significantly noticed only in the cortical bone (alveolar ridge) area. External threads cause significant stress concentrations in interfacial stresses in otherwise smoothly varying regions. This work shows that the presence of external threads could cause significant variations in both normal and shear stresses along the bone–implant interface, but not reduction in shear stress as previously thought.

Keywords: Dental implants, Interfacial stresses, Load transfer, Osseointegration, External threads, Implant contour

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(10)00100-4

doi:10.1016/j.jbiomech.2010.02.017

Journal of Biomechanics
Volume 43, Issue 9 , Pages 1761-1770, 18 June 2010