Journal of Biomechanics
Volume 43, Issue 12 , Pages 2301-2308, 26 August 2010

Effects of increased chronic loading on articular cartilage material properties in the Lapine tibio-femoral joint

  • Maria L. Roemhildt

      Affiliations

    • Department of Orthopaedics and Rehabilitation, 95 Carrigan Drive, University of Vermont, Burlington, VT 05405, USA
    • Corresponding Author InformationCorresponding author. Tel.: +18026563823; fax: +18026564247.
  • ,
  • Kathryn M. Coughlin

      Affiliations

    • Department of Orthopaedics and Rehabilitation, 95 Carrigan Drive, University of Vermont, Burlington, VT 05405, USA
  • ,
  • Glenn D. Peura

      Affiliations

    • Department of Orthopaedics and Rehabilitation, 95 Carrigan Drive, University of Vermont, Burlington, VT 05405, USA
  • ,
  • Gary J. Badger

      Affiliations

    • Department of Biometry and Biostatistics, University of Vermont, Burlington, VT 05405, USA
  • ,
  • Dave Churchill

      Affiliations

    • Microstrain, Williston, VT, USA
  • ,
  • Braden C. Fleming

      Affiliations

    • Warren Alpert Medical School at Brown University, Providence, RI, USA
  • ,
  • Bruce D. Beynnon

      Affiliations

    • Department of Orthopaedics and Rehabilitation, 95 Carrigan Drive, University of Vermont, Burlington, VT 05405, USA

Accepted 28 April 2010. published online 20 May 2010.

Abstract 

Methods of producing relevant and quantifiable load alterations in vivo with which to study load-induced cartilage degeneration analogous to osteoarthritis are limited. An animal model was used to investigate the effects of increased chronic loads on articular cartilage. Mature rabbits were randomized into one of three experimentally loaded groups and a fourth unoperated control group. A mechanical-loading device was skeletally fixed to the hind limb of animals in the loaded groups. Engaging the device resulted in an additional load of 0%, +22% or +44% body weight to the medial compartment of the experimental knee, while allowing normal joint function. Following a 12-week loading protocol, a creep-indentation test and needle probe test were used to determine the biphasic material properties and thickness of the cartilage at four locations of each femoral and tibial condyle of the experimental and contralateral limbs. Analyses of covariance were performed to compare outcome measures across the treatment groups. The effect of increased load was site and load-level specific with alterations of material properties and thickness most prominent in the posterior region of the medial compartment of the tibia. At this site, permeability increased 128% and thickness increased 28% in the +44% body weight group relative to the 0% body weight group. This model of altered chronic loading initiated changes in the material properties to the articular cartilage at the sites of increased load over 12-weeks that were consistent with early degenerative changes suggesting that increased tibio-femoral loading may be responsible for the alterations. This work begins to elucidate the chronic-load threshold and the time course of cartilage degeneration at different levels of altered loading.

Keywords: Animal model, Articular cartilage, Altered loading

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(10)00259-9

doi:10.1016/j.jbiomech.2010.04.035

Journal of Biomechanics
Volume 43, Issue 12 , Pages 2301-2308, 26 August 2010