Journal of Biomechanics
Volume 43, Issue 15 , Pages 2908-2914, 16 November 2010

Influence of the change in stem length on the load transfer and bone remodelling for a cemented resurfaced femur

  • Bidyut Pal

      Affiliations

    • Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, Kharagpur 721 302, West Bengal, India
  • ,
  • Sanjay Gupta

      Affiliations

    • Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, Kharagpur 721 302, West Bengal, India
    • Corresponding Author InformationCorresponding author. Tel.: +913222282958; fax: +913222282277.
  • ,
  • Andrew M.R. New

      Affiliations

    • Bioengineering Science Research Group, School of Engineering Sciences, University of Southampton, Southampton SO17 1BJ, United Kingdom

Accepted 16 July 2010. published online 23 August 2010.

Abstract 

The effect of a short-stem femoral resurfacing component on load transfer and potential failure mechanisms has rarely been studied. The stem length has been reduced by approximately 50% as compared to the current long-stem design. Using 3-D FE models of natural and resurfaced femurs, the study is aimed at investigating the influence of a short-stem resurfacing component on load transfer and bone remodelling. Applied loading conditions include normal walking and stair climbing. The mechanical role of the stem along with implant–cement and stem–bone contact conditions was observed to be crucial. Shortening the stem length to half of the current length (long-stem) led to several favourable effects, even though the stress distributions in the implant and the cement were similar in both the cases. The short-stem implant led not only to a more physiological stress distribution but also to bone apposition (increase of 20–70% bone density) in the superior resurfaced head, when the stem–bone contact prevailed. This also led to a reduction in strain concentration in the cancellous bone around the femoral neck–component junction. The normalised peak strain in this region was lower for the short-stem design as compared to that of the long-stem one, thereby reducing the initial risk of neck fracture. The effect of strain shielding (50–75% reduction) was restricted to a small bone volume underlying the cement, which was approximately half of that of the long-stem design. Consequently, bone resorption was considerably less for the short-stem design. The short-stem design offers better prospects than the long-stem resurfacing component.

Keywords: Hip, Resurfacing, Short-stem, Finite element analysis, Bone remodelling, Bone density

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(10)00408-2

doi:10.1016/j.jbiomech.2010.07.017

Journal of Biomechanics
Volume 43, Issue 15 , Pages 2908-2914, 16 November 2010