Journal of Biomechanics
Volume 32, Issue 12 , Pages 1331-1335, December 1999

A new methodology to measure load transfer through the forearm using multiple universal force sensors

Musculoskeletal Research Center, Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, PO Box 71199, Pittsburgh, PA 15213, USA

Accepted 9 July 1999.

Abstract 

Previous approaches to measuring forces in the forearm have made the assumption that forces acting in the radius and ulna are uniaxial near the wrist and elbow. To accurately describe forces in the forearm and the forces in the interosseous ligament, we have developed a new methodology to quantitatively determine the 3-D force vectors acting in forearm structures when a compressive load is applied to the hand. A materials testing machine equipped with a six degree-of-freedom universal force–moment sensor (UFS) was employed to apply a uniaxial compressive force to cadaveric forearms gripped at the hand and humerus. Miniature UFSs were implanted into the distal radius and proximal ulna to measure force vectors there. A 3-D digitizing device was used to measure transformations between UFS coordinate systems, utilized for calculating the force vectors in the distal ulna, proximal radius, and the interosseous ligament (IOL). This method was found to be repeatable to within 3N, and accurate to within 2N for force magnitudes. Computer models of the forearm, generated from CT scans, were used to visualize the force vectors in 3-D. Application of this methodology to eight forearm specimens showed that the radius carries most of the load at the wrist while force in the IOL relieves load acting in the radius at the mid-forearm. For a 136 N applied hand force, the force in the IOL was 36±21N. Advantages of this methodology include the determination of 3-D force vectors, especially those in the IOL, as well as computer generated 3-D visualization of results.

Keywords:  Forearm load transfer, Universal force–moment sensor, Computed tomography, Kinematics, Computer visualization

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0021-9290(99)00138-4

Journal of Biomechanics
Volume 32, Issue 12 , Pages 1331-1335, December 1999